    The device is designed to measure microwave signal
    power from 50 MHz up to 6/26.5/50 GHz. The SPS power
    sensor is used for manufacturing and monitoring of RF and
    MW devices as well as for tuning and testing of microwave
    assemblies used in communications, instrument engineering
    and measuring equipment.

    • Modification

      1. SPS06 (50 MHz…6 GHz)
      2. SPS26 (50 MHz…26.5 GHz)
      3. SPS50 (50 MHz…50 GHz)
    • Technical features

       

      The main abilities of SPS sensors are following:

      • operation as a part of a measuring system;
      • absolute and relative power measurement modes;
      • displaying results in linear and logarithmic scales;
      • time-gated measurement with signal envelope indication (SPS06);
      • logging measured data in computer file.

      Power sensors are provided with connectors for external synchronization. SCPI-based text command system provides device integration with automated instrumentation systems.

      Software

      SPS-Client software is used to interact with SPS power sensor.

      • user-friendly interface;
      • saving measurement data to file;
      • setting of compensation for attenuation/amplification by external devices;
      • graphic display of measurement data;
      • signal-wave envelope display (in accumulation mode, available for SPS06);
      • time markers to monitor signal power variations;
      • saving/downloading profiles for measuring circuits.

    • Technical Specifications

      SPS06 SPS26 SPS50
      Operating frequency range 50 MHz …6 GHz 50 MHz …26.5 GHz 50 MHz …50 GHz
      Power measurement range −50…+20 dBm (10 nW…100 mW)
      Allowable measurement error ±10% ±7% ±7% (50 MHz ... 26.5 GHz)
      ±10% (26.5 ... 40 GHz)
      ±12% (40 ... 50 GHz)
      Input VSWR, max 1.2 1.20 (50 MHz…26.5 GHz)
      1.45 (26.5…40 GHz)
      1.80 (40…50 GHz)
      Wave impedance 50 Ω
      Video band of meter, typical 100 kHz
      Measurement time
      Time required to establish operating mode, max. 5 sec
      Single measurement, max. 20 meas./sec
      On-line measurements (in accumulation mode), min. 12000 meas./sec
      Connector types
      Microwave output Type N, SMA
      (male or female)
      3.5 mm (male) 2.4 mm (male)
      Trigger input/output MCX, female
      Power and control USB 2.0 Mini-B
      Operating temperature range +5…+50 °С
      Dimensions (L × W × H) 125 × 65 × 25 mm 135 × 65 × 25 mm
      Weight 0.25 kg 0.35 kg